Programming Your Application
6-7
650V AC Drive
MMI Parameters Table
Display Parameter Description Range Default
SET::IN Menu
DIN 1 INVERT Inverts the value of the signal, TRUE or FALSE. 0= FALSE
1= TRUE
0
DIN 2 INVERT As
S
IP01 As
S
IP01 0
DIN 3 INVERT As
S
IP01 As
S
IP01 0
DIN 4 INVERT As
S
IP01 As
S
IP01 0
DIN 5 INVERT As
S
IP01 As
S
IP01 1
DIN 6 INVERT As
S
IP01 As
S
IP01 0
DIN 7 INVERT As
S
IP01 As
S
IP01 0
AIN 1 SCALE -300.0 to 300.0% 100.0%
AIN 1 OFFSET -300.0 to 300.0% 0.0%
AIN 1 TYPE
VALUE
+
SCALE
OFFSET
X
INPUT
TYPE
UNPROCESSED
0 to 100% of selected TYPE
0= 0-10V
1= 0-5V
0
AIN 2 SCALE -300.0 to 300.0% 100.0%
AIN 2 OFFSET -300.0 to 300.0% 0.0%
AIN 2 TYPE
VALUE
+
SCALE
OFFSET
X
INPUT
TYPE
UNPROCESSED
0 to 100% of selected TYPE
0= 0-10V
1= 0-5V
2= 0-20mA
3= 4-20mA
3
DIN 1 VALUE
F
The TRUE or FALSE input (after any inversion) 0=FALSE
1=TRUE
0
DIN 2 VALUE
F
The TRUE or FALSE input (after any inversion) 0=FALSE
1=TRUE
0
DIN 3 VALUE
F
The TRUE or FALSE input (after any inversion) 0=FALSE
1=TRUE
0
DIN 4 VALUE
F
The TRUE or FALSE input (after any inversion) 0=FALSE
1=TRUE
0
DIN 5 VALUE
F
The TRUE or FALSE input (after any inversion) 0=FALSE
1=TRUE
0
DIN 6 VALUE
F
The TRUE or FALSE input (after any inversion) 0=FALSE
1=TRUE
0
DIN 7 VALUE
F
The TRUE or FALSE input (after any inversion) 0=FALSE
1=TRUE
0
AIN 1 VALUE
F
The input reading with scaling and offset applied
⎯.x%
—.x%
AIN 2 VALUE
F
The input reading with scaling and offset applied
⎯.x%
—.x%
Lefflersgatan 1, SE-754 50 Uppsala, SWEDEN +46 (0)18-65 70 00 +46 (0)18-10 74 78 info@regal.se www.regal.se