EasyManuals Logo

Parker GT Series User Manual

Parker GT Series
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
54
Gemini GT Hardware Installation Guide
Enable Input (required)
To enable the drive and energize the motor, you must connect the enable input
(pin 1) to digital ground (pin 2). The next drawing shows the internal circuit.
Internal Connections
Same circuit design
as Enable
VINref
Enable
Digital Ground
Reset
26
1
2
3
DRIVE I/O Connector
+24V
6.81 K
10 K
20.0 K
18.2 K
12.0 K
33.0 K
33.0 K
-
+
Threshold
Sense
Inputs internally pulled up to
+24V, unless you connect an
external 5 – 24VDC supply to
the VINref terminal.
Input voltage range:
0 – 24VDC.
Switching Levels:
Low 1/3 VINref voltage
High 2/3 VINref voltage
Active Level:
Active
low
Optional normally closed switch,
recommended for manual disable.
Enable Input and Reset Input
Reset Input (optional)
The reset and enable inputs use the same circuit design, as the drawing above
shows. To reset the drive, temporarily connect the reset input (pin 3) to digital
ground (pin 2). Reset begins when pin 3 is grounded. The drive will begin its
power up sequence upon disconnection of pin 3 from ground.
VINref – Voltage Input Reference (optional)
Use VINref (pin 26) to set the input reference voltage for the enable, reset, and
digital inputs.
It is not necessary for you to make connections to VINref. If you connect nothing,
then the enable, reset, and inputs are internally pulled up to +24VDC. This is the
factory default condition.
If you connect an external 5 24VDC power supply to VINref, then the input
switching thresholds become:
Low 1/3 VINref
High 2/3 VINref
(Default, with VINref at internal +24VDC: Low < 8V; High > 16V)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker GT Series and is the answer not in the manual?

Parker GT Series Specifications

General IconGeneral
Horsepower0.5 to 15 HP
FeedbackTachometer
Protection RatingIP20
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Operating ModesSpeed Control, Torque Control