12
Proportional Pressure Valves
Series RE*T / R*V
Operation Manual
Parker Hannifin Corporation
RE_-R_V obe_24-45-A-B 5715-651 UK 29.01.19
Mounting
• Compare valve type (located on the name plate)
with part list resp. circuit diagram.
• The valve may be mounted fix or movable in
any direction.
• Verify the mounting surface for the valve. Une-
veness of 0.01 mm/100 mm, surface finish of
6.3 µm are tolerable values.
Keep clean valve mounting surface and work
environment!
• Remove protection plate from the valve moun-
ting surface
• Check the proper position of the valve ports
and the O-rings.
• Mounting bolts:
use property class ISO 4762-12.9
• Tighten the bolts crisscross with the following
torque values acc. to table below
4. Mounting / Installation
Scope of Supply
Please check immediately after receiving the valve,
if the content is matching with the specified scope
of supply. The delivery includes:
• valve
• operation manual
The central connector assembly as well as the
parametrizing cable has to be ordered separately
and are not included in the delivery.
Please check the delivery immediately after
receiving the shipment for apparent damages
due to shipping. Report shipment losses at
once to the carrier, the insurance company
and the supplier!
Valve type Bolt dimensions Torque value Ordering number
RE06M*T 4 pcs. M5x30 mm 7.6 Nm BK375
RE10M*T/R4V03 4 pcs. M10x35 mm 63 Nm BK505
RE25M*T/R4V06 4 pcs. M10x45 mm 63 Nm BK485
RE32M*T/R4V10 6 pcs. M10x45 mm 63 Nm BK506
RE10R*T/R6V03 4 pcs. M12x45 mm 108 Nm BK494
RE25R*T/R6V06 4 pcs. M16x70 mm 264 Nm BK366
RE32R*T/R6V10 4 pcs. M18x75 mm 398 Nm BK507
RE16E*T 4 pcs. M8x40 mm 31.8 Nm BK414
RE25E*T 4 pcs. M12x50 mm 108 Nm BK391
RE32E*T 4 pcs. M16x55 mm 264 Nm BK415
RE40E*T 4 pcs. M20x70 mm 517 Nm BK416
RE50E*T 4 pcs. M20x75 mm 517 Nm BK417
RE63E*T 4 pcs. M30x100 mm 1775 Nm BK418
R5V * * *
Insufficient condition of the valve mounting
surface migth create malfunction!
Incorrect mounting resp. bolt torque may
result in abrupt leakage of hydraulic fluid on
the valve ports.
Available bolt kits
Operation Limits
The valve may be operated within the determined
limits only. Please refer to the “technical data“
section as well as to the “characteristic curves“ in
the catalog.
Follow the environmental conditions! Unallo-
wable temperatures, shock load, aggresive
chemicals exposure, radiation exposure,
illegal electromagnetic emissions may result
in operating trouble and may lead to failure!
Follow the operating limits listed in the “spe-
cifications“ table!
* The dimension of the screws resp. tie rods
depends on the used SAE flanges and on the
number of SAE valves.