Page 8 of 24
TAMPER EVIDENT NECK BANDING AND SHRINKSLEEVE LABELING MACHINERY
8 Sheehan Avenue, South Norwalk, CT 06854 USA 203-853-1516 F 203-854-0834 www.pdc-corp.com
The pneumatic precision regulator adjusts the
flow for steam going inside the tunnel. The
air pressure setting at the pneumatic
transducer should be targeted at 20 psi
initially – range 18-22 psi.
The thermodynamic steam trap opens to
release condensate. It is normal for it to
exhaust intermittently, but if it exhausts
continually, then there may be debris on the
seat that may be causing it to stay open.
Please see the Troubleshooting Section below, for more details, before taking
any corrective action, and do not attempt to fix any part of this unit if you are not
trained and comfortable doing so, as the discharge can
be sudden and hot!
PNEUMATIC
TRANSDUCER
GAUGE