EasyManua.ls Logo

Peavey DPM C8p - 4.11 Changing the Curves Offset; 4.12 Changing the Curves Scale

Peavey DPM C8p
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.11
Changing
the
Curve’s
Offset
Modify
the
ROM
curve
by
first
changing
the
offset.
Place
the
cursor
on
the
Offset
parameter
and
select
an
offset
amount
from
+100
to
-100
Positive
numbers
add
a
constant
amount
of
base
pressure
to
the
curve;
in
other
words,
the
pressure
will
not
be
lower
than
this
value.
Negative
values
subtract
a
constant
amount
from
the
pressure
curve
(although
the
resulting
pressure
value
cannot
be
lower
than
O’).
You
may
want
to
avoid
positive
values
here,
since
they
can
cause
a
jump
from
zero
to
the
offset
value
the
first
time
you
press
down
after
the
preset
is
recalled.
4
.12
Changing
the
Curve
s
Scale
Further
modify
the
ROM
curve
by
changing
the
scale.
Place
the
cursor
on
the
Scale
parameter
and
select
die
desired
scale.
'1'his
value
multiplies
all
pressure
values
by
a
constant,
from
1
%
to
200
%
(100%
does
not
affect
the
selected
value).
11'
necessary,
continue
changing
the
offset
and
scale
parameters
until
the
graph
that
displays
the
relation
of
MIDI
output
to
input
pressure
shows
the
desired
curve
and
pressing
on
the
keyboard
produces
the
desired
feel.
Note:
The
Pressure
Curve
is
used
for
the
C8s
pressure
regardless
of
what
the
pressure
controller
is
assigned
to
do.
Other
controllers
(sliders,
etc.)
assigned
to
send
Channel
Pressure
will
not
be
processed
by
the
curve.
Also
Note:
Incoming
MIDI
that
is
merged
through
the
Ranges
will
not
be
processed
through
this
curve
since
it
is
not
part
of
the
preset.
Only
the
C8
keybed’s
pressure
will
go
through
the
curve.
SECTION
4E
GLOBAL
,
FOOTSWITCH
POLARITY
SCREEN
The
four
footswitches
can
have
either
positive
or
negative
polarity,
meaning
that
you
can
use
either
normally
open
or
normally
closed,
momentary
push-button
switches.
If
pressing
a
footswitch
does
not
cause
the
intended
action
but
releasing
it
does,
then
use
the
polarity
function
to
change
the
footswitch
polarity.
Place
the
cursor
on
the
polarity
parameter
for
the
desired
footswitch,
and
select
between
+
(closing
the
switch
initiates
an
action)
or
-
(opening
the
switch
initiates
an
action).
SECTION
4F
GLOBAL
VERSION
SCREEN
This
screen
shows
the
software
version
currently
installed
in
yourC8,
along
with
the
date
and
time
that
Peavey
released
that
version.

Table of Contents

Related product manuals