3
2005 Doctor Martin Luther King Jr Street
Indianapolis, IN 46202
Rev 07-2021
MATERIALS AND EQUIPMENT REQUIRED
The materials and equipment necessary for installation will vary with the size of the
pump and the type of the installation. The following list is offered as a guide only.
1. Bulk Material
Pipe thread compound (sealant)
Lubricating oil
Grease (see Table 3a on page 32).
Turbine oil (see Table 3b on page 33).
Lubricant (see Recommended Lubricants on page 32)
Petroleum-based solvent (if permissible by local EPA codes)
Non-shrinking grouting material
Anti-seize or anti-galling compound (for shaft and bolt threads)
2. Rigging Material
Mobile power hoist or traveling crane
Box clamps (2 pairs) - for flanged columns
Slings - wire and nylon; appropriate for equipment being lifted
Eyebolts
Clevises (shackles) - for use with eye-bolts
Lumber - sized to support pump shaft sections to maintain straightness and protect
threads
Support beams - size, length and quantity required to use with elevator or box clamps
and support the weight of the assembled pump less the driver
3. Hand Tools
Pipe wrench (minimum of 2) - sizes appropriate to equipment
Chain tongs (minimum of 2) - sizes appropriate to equipment
Pipe cutter or hacksaw
Clean rags
Feeler gauges
Set of mechanic’s hand tools, including: files, scrapers, wire brush, pliers, wire
cutters, pocket knife, wrenches
Dial indicator and mounting base
Machinist’s level (carpenter’s level not sufficiently accurate)