Questions and Answers

  • D
    David WhiteSep 8, 2025
    How to stop foam in Pego Humidifier with high conductivity?
    • K
      katherinelopezSep 8, 2025
      If your Pego Humidifier is producing foam and triggering the maximum level alarm E1 because of water conductivity above 1300 µS/cm, diminish the de-concentration discharge time by setting S2 to a lower value.
  • A
    Alicia HernandezSep 9, 2025
    How do I fix foam production in my Pego Humidifier?
    • J
      johnbishopSep 10, 2025
      If your Pego Humidifier is producing foam, triggering the maximum level alarm E1 because of suspended particles produced by oils or greases in the inlet line, carry out several complete cylinder flushes with manual emptying immediately after complete filling.
  • S
    Scott WebsterSep 12, 2025
    What causes E2 alarm on my Pego Humidifier?
    • M
      Marie WatsonSep 12, 2025
      If your Pego Humidifier is blocked with an E2 alarm, verify the condition of the humidity duct sensor. This is due to a functional fault of the humidity duct sensor.
  • R
    raycampbellSep 13, 2025
    Why is my Pego Humidifier blocked with En alarm?
    • P
      Peter BurtonSep 13, 2025
      If your Pego Humidifier is blocked with an En alarm, verify the right connection between the SLIM controller and TLD electronic. This is due to a lack of connection between them.
  • K
    Karen Hernandez DVMSep 15, 2025
    What does E0 alarm mean on Pego Humidifier?
    • T
      Taylor FullerSep 15, 2025
      If your Pego Humidifier is blocked with an E0 alarm, verify the condition of the humidity sensor. This is due to a functional fault of the humidity sensor.
  • R
    Russell ConwaySep 18, 2025
    Why Pego Humidifier alternately displays OFF and normal visualization?
    • S
      Scott FisherSep 18, 2025
      If your Pego Humidifier is on but alternately displays OFF and normal visualization and it doesn’t fill water, verify enabling on terminal blocks 1 and 2 on the 100 Master card, because there might be a missing enabling signal.