EasyManua.ls Logo

Pentair EasyTouch 8 and 4 - Glossary of Terms

Pentair EasyTouch 8 and 4
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
EasyTouch Load Center Installation Guide
Glossary
Control Panel: The EasyTouch control panel with flexible hinge. Installed in upper portion of
EasyTouch load center to control the EasyTouch pool and spa system.
EMI (Electromagnetic interference) filter: Protective circuit element that must be used between
the IntelliChlor transformer and supply lines.
High Voltage Panel/Compartment: Removable panel for the high voltage compartment of
EasyTouch load center. The high voltage wiring including circuit breakers, relays, GFCI and optional
IntelliChlor transformer/filter.
Indoor Control Panel: This 9 or 13 button remote controller with LCD (liquid crystal display) is
wired to the motherboard in the EasyTouch load center. The control panel can be wall mounted
inside a house to control the EasyTouch system.
IntelliChlor: Electronic salt chlorinator. Uses a process known as electrolysis to produce sodium
hypochlorite (liquid chlorine) from a low concentration of salt added to the pool water. Model IC 20
Cell (P/N 520554) for pools up to 20,000 U.S. gallons (75 liters) and model IC 40 Cell (P/N 520555)
for pools up to 40,000 U.S. gallons (151 liters).
iS4: Four function spa-side remote. Spa wall or deck mounted.
Load Center: Metal enclosure with power relays, transformer, and circuit breakers. Used for
distributing power for controlling EasyTouch Systems. Also known as the “sub-panel.
Low Voltage Compartment: Top compartment of EasyTouch load center for all low voltage wiring.
Low Voltage Raceway: Vertical space in the left side of EasyTouch load center for low voltage
cabling.
Motherboard: The circuit board mounted behind the EasyTouch control panel.
Relay Circuits: The circuits that control the relays on the motherboard. Connectors on top edge of
the circuit board.
Screw Terminal Connector: Removable connector that may attach to circuit board with multiple
sockets (anywhere from 2 to 6) to receive wires from controllers and sensors; wires held by screw
terminals; multiple wires of a small enough gauge (usually 22 AWG) may be coupled to a single
socket of a terminal connector.
Salt Chlorine Generator (SCG): Automated pool chlorinator that sanitizes using salt water (see
IntelliChlor).
Transceiver: Used by the EasyTouch wireless control panel. Circuit board with attached antenna
that can send and receive radio frequency (wireless) transmissions.