11 - MASTER PROGRAMMING MODE
CHART SXT
CAUTION
Before entering Master Programming, please
contact your local professional water dealer.
Master Programming Options
Abbreviation Parameter Option Abbriviation Options
DF Display Format GAL Gallons
Ltr Liters
VT Valve Type 5800 5800 Control Valve
RF Regenerant Flow dF1b Standard Downow Single Backwash
dF2b Standard Downow Double Backwash
Fltr Filter
AIO Air Injection Oxidizer
dFFF Downow Fill First
UFbd Upow Brine First
UFFF Upow Fill First
Othr Other
CT Control Type Fd Meter (Flow) Delayed
FI Meter (Flow) Immediate
tc Time Clock
dAY Day of Week
C Unit Capacity Unit Capacity (Grains)
H Feedwater Hardness Hardness of Inlet Water (Grains)
RS Reserve Selection SF Percentage Safety Factor
rc Fixed Reserve Capacity
SF Safety Factor Percentage of the system capacity to be used as a reserve
RC Fixed Reserve Capacity Fixed volume to be used as reserve
DO Day Override The system's day override setting
RT Regen Time The time of day the system will regenerate
BW, BD, RR, BF Regen Cycle Step Times The time duration for each regeneration step. Adjustable from OFF and
0-199 minutes.
NOTE: If "Othr" is chosen under "Valve Type", then C1, C2,
..., C20 will be displayed along with available cycle
steps RR, BD, SR, BW, RF, SP. LC denotes the Last
Cycle.
D1, D2, D3, D4,
D5, D6, & D7
Day of Week Settings Regeneration setting (On or Off) for each day of the week on day-of-
week systems.
CD Current Day The Current day of the week
FM Flow Meter Type P0.7 3/4" Paddle Wheel Meter
t0.7 3/4" Turbine Meter
P1.0 1" Paddle Wheel Meter
t1.0 1" Turbine Meter
P1.5 1.5" Paddle Wheel Meter
t1.5 1.5" Turbine Meter
P2.0 2" Paddle Wheel Meter
Gen Generic or Other non-Fleck Meter
K Meter Pulse Setting Meter pulses per gallon for generic/other ow meter
NOTE: Some items may not be shown depending on timer
conguration. The timer will discard any changes
and exit Master Programming Mode if any button is
not pressed for 5 minutes.
Fleck 5800 LXT & SXT Downow/Upow MR12 • 11