12 - MASTER PROGRAMMING MODE
SXT
When the Master Programming Mode is entered, all available
option setting displays may be viewed and set as needed.
Depending on current option settings, some parameters cannot
be viewed or set.
Setting the Time of Day
1. Press and hold either the Up or Down buttons until the
programming icon replaces the service icon and the
parameter display reads TD.
2. Adjust the displayed time with the Up and Down buttons.
3. When the desired time is set, press the Extra Cycle button
to resume normal operation. The unit will also return to
normal operation after 5 seconds if no buttons are pressed.
Figure 13
Entering Master Programming Mode
Set the Time of Day display to 12:01 P. M. Press the Extra
Cycle button (to exit Setting Time of Day mode). Then
press and hold the Up and Down buttons together until the
programming icon replaces the service icon and the display
format screen appears.
Exiting Master Programming Mode
Press the Extra Cycle button to accept the displayed settings
and cycle to the next parameter. Press the Extra Cycle
button at the last parameter to save all settings and return to
normal operation. The control will automatically disregard any
programming changes and return to normal operation if it is
left in Master Programming mode for 5 minutes without any
keypad input.
Resets
Soft Reset
Press and hold the Extra Cycle and Down buttons for 25
seconds while in normal Service mode. This resets all
parameters to the system default values. Not reset are the
volume remaining in meter immediate or meter delayed
systems and days since regeneration in the time clock system.
Master Reset
Hold the Extra Cycle button while powering up the unit. This
resets all of the parameters in the unit. Check and verify the
choices selected in Master Programming Mode.
1. Display Format (Display Code DF)
This is the rst screen that appears when entering Master
Programming Mode. The Display Format setting species
the unit of measure that will be used for volume and how
the control will display the Time of Day. This option setting is
identied by "DF" in the upper left hand corner of the screen.
There are two possible settings.
Display Format
Setting
Unit of Volume Time Display
GAL U.S. Gallons 12-Hour AM/PM
Ltr Liters 24-Hour
Figure 14
2. Valve Type (Display Code VT)
Press the Extra Cycle button. Use the display to set the Valve
Type. 5800 is the only currently available valve type.
3. Regenerant Flow (Display Code RF)
Press the Extra Cycle button. The Regenerant Flow Setting
species the type of cycle that the valve follows during
regeneration. Note that some valve types require the valve
be built with specic subcomponents. Ensure the valve is
congured properly before changing the Valve Type setting.
This option setting is identied by "RF" in the upper left hand
corner of the screen. There are 8 possible settings.
Abbreviation Parameter
dF1b Standard Downow Single Backwash
dF2b Standard Downow Double Backwash
Fltr Filter
AIO Air Injection Oxidizer
dFFF Downow Fill First
UFbd Upow Brine First
UFFF Upow Fill First
Othr Other
Figure 15
4. Control Type (Display Code CT)
Press the Extra Cycle button. Use this display to set the
Control Type. This species how the control determines when
to trigger a regeneration. For details on how the various
options function, refer to the "Timer Operation SXT" section
of this service manual. This option setting is identied by "CT"
in the upper left hand corner of the screen. There are four
possible settings.
Abbreviation Parameter
Fd Meter (Flow) Delayed
FI Meter (Flow) Immediate
tc Time Clock
dAY Day of Week
12 • MR12 Fleck 5800 LXT & SXT Downow/Upow