9 - MASTER PROGRAMMING MODE LXT
CAUTION
Before entering Master Programming, please
contact your local professional water dealer.
Time of
Day
Time of
Backwash
Backwash
Length
Filter
Capacity
Capacity
Remaining
Resin
PM
MODE
Figure 7
Press Mode button to cycle through programming options.
When timer is powered up, the display position will point to
Time of Day. Set time of day by holding the Up or Down arrow.
Hold the Extra Cycle button until the Program icon disappears
to save the current time.
5800 Meter Downow/Upow
MODE
12:00
R
CaCO³
NaCl
Time Of Day
Time Of
Regen
Salt
Amount
Hardness
Capacity
Resin
Figure 8
1. Press the Mode button to advance to Time of Regen. Push
the Up or Down arrow to adjust the time of regeneration.
2. Press the Mode button again to advance to Salt Amount.
Press the Up or Down arrow to adjust your salt dosage.
English timer range is 3-18 lbs. Metric timer range is 50-290
grams per liter.
3. Press the Mode button again to advance to Hardness.
Press the Up or Down arrow to adjust the setting to your
hardness. English timer range is 3 to 200 gpg. Metric timer
range is 30-200 mgl.
4. Press the Mode button again to advance to Capacity
Remaining. This is the amount of gallons the unit can treat.
This is not adjustable.
5. Press the Mode button again to advance to Resin. Use the
Up or Down arrow to adjust the amount of CuFt resin in
your tank. English timer range is 0.25-3.0 CuFt. Metric timer
range is 5-100 liters.
6. Hold the Extra Cycle button until the Program icon
disappears to save your programming.
7. If you are just changing one program step, hold the Extra
Cycle button until the Program icon disappears to save your
changes. If you do not hold the Extra Cycle button until the
Program icon disappears your changes will not be saved.
NOTE: This unit has a day of the week reserve. It
calculates a reserve for each day of the week based
on the past 4 weeks.
5800 Time Clock Downow/Upow
12:00
NaCl
31
MODE
Time Of Day
Time Of
Regen
Salt
Amount
Days Between
Regens
Days to
Regen
Resin
Figure 9
1. Press the Mode button to advance to Time of Regen. Push
the Up or Down arrow to adjust the time of regeneration.
2. Press the Mode button again to advance to Salt Amount.
Press the Up or Down arrow to adjust your salt dosage.
English timer range is 3-18 lbs. Metric timer range is 50-290
grams per liter.
3. Press the Mode button again to advance to Days Between
Regens. Range is 1 to 30 days.
4. Press the Mode button again to advance to Days to Regen.
This is not adjustable.
5. Press the Mode button again to advance to Resin. Use the
Up or Down arrow to adjust the amount of CuFt resin in
your tank. English timer range is 0.25-3.0 CuFt. Metric timer
range is 5-100 liters.
6. Hold the Extra Cycle button until the Program icon
disappears to save your programming.
7. If you are just changing one program step, hold the Extra
Cycle button until the Program icon disappears to save your
changes. If you do not hold the Extra Cycle button until the
Program icon disappears your changes will not be saved.
Extra Cycle
Button
Mode
Button
Up Arrow Down Arrow
8 • MR12 Fleck 5800 LXT & SXT Downow/Upow