Loading...
9 - MASTER PROGRAMMING MODE LXT
continued
5800 Filter Meter
12:00
R
R
MODE
Time Of Day
Time Of
Regen
Backwash
Length
Filter
Capacity
Capacity
Remaining
Resin
Figure 10
Figure 10
1. Press the Mode button to advance to Time of Backwash.
Push the Up or Down arrow to adjust the time of backwash.
2. Press the Mode button again to advance to Backwash
Length. Press the Up or Down arrow to adjust your
backwash length. Range is 1-30 minutes.
3. Press the Mode button again to advance to Filter Capacity.
Press the Up or Down arrow to adjust the setting for lter
capacity. English timer range is 100-90,000 gallons. Metric
timer range is 1-900 cubic meters.
4. Press the Mode button again to advance to Capacity
Remaining. This is not adjustable.
5. Press the Mode button again to advance to Resin. Use the
Up or Down arrow to adjust the amount of CuFt resin in
your tank. English timer range is 0.25-3.0 CuFt. Metric timer
range is 5-100 liters.
6. Hold the Extra Cycle button until the Program icon
disappears to save your programming.
7. If you are just changing one program step, hold the Extra
Cycle button until the Program icon disappears to save your
changes. If you do not hold the Extra Cycle button until the
Program icon disappears your changes will not be saved.
NOTE: This unit has a day of the week reserve. It
calculates a reserve for each day of the week based
on the past 4 weeks.
5800 Filter Time Clock
12:00
31
MODE
Time Of Day
Time Of
Regen
Backwash
Lenght
Days Between
Regens
Days to
Regen
Resin
Figure 11
Figure 11
1. Press the Mode button to advance to Time of Backwash.
Push the Up or Down arrow to adjust the time of backwash.
2. Press the Mode button again to advance to Backwash
Length. Press the Up or Down arrow to adjust your
backwash length. Range is 1-30 minutes.
3. Press the Mode button again to advance to Days Between
Regens. Range is 1 to 30 days.
4. Press the Mode button again to advance to Days to
Backwash. This is not adjustable.
5. Press the Mode button again to advance to Resin. Use the
Up or Down arrow to adjust the amount of CuFt resin in
your tank. English timer range is 0.25-3.0 CuFt. Metric timer
range is 5-100 liters.
6. Hold the Extra Cycle button until the Program icon
disappears to save your programming.
7. If you are just changing one program step, hold the Extra
Cycle button until the Program icon disappears to save your
changes. If you do not hold the Extra Cycle button until the
Program icon disappears your changes will not be saved.
Fleck 5800 LXT & SXT Downow/Upow MR12 • 9