5800 - 0.75 ft
3
5800 - 1.0 ft
3
Test Model
5800 - 1.25 ft
3
5800 - 1.5 ft
3
5800 - 1.75 ft
3
5800 - 2.0 ft
3
"Rated Service Flow - gpm
with an upper collector"
9 11 11 10.5 12.5 12
Pressure Drop at Rated Service Flow
15 15 15 15 15 15
"Rated Capacity
(grains @ lbs. of salt)"
12,809 @ 2.81
21,051 @ 6.75
24,210 @ 11.25
17,930 @ 3.75
29,467 @ 9.0
33,889 @ 15.0
22,412 @ 4.7
36,833 @ 11.25
42,361 @ 18.75
26,895 @ 5.6
44,200 @ 13.5
50,833 @ 22.5
31,377 @ 6.6
51,567 @ 15.75
59,305 @ 26.25
35,860 @ 7.5
58,934 @ 18.0
67,778 @ 30.0
Rated Eciency
(grains/lb. Salt @ lbs. of salt)
4,550 @ 2.81 4,780 @ 3.75 4,780 @ 4.7 4,780 @ 5.6 4,780 @ 6.6 4,780 @ 7.5
Maximum Flow Rate During
Regeneration (gpm)
1.7 2 2.4 2.4 3.5 3.5
Resin Volume - ft
3
Resin Type - 8% strong acid cation
0.75 1 1.25 1.5 1.75 2
Tank size
8" x 44" 9" x 48" 10" x 47" 10" x 54" 12" x 48" 12" x 52"
Backwash 8 8 8 8 8 8
Brine Draw & Slow Rinse
@ lb of Salt
50 @ 3.0
62 @ 6.75
78 @ 11.25
52 @ 3.75
70 @ 9.0
90 @ 15.0
43 @ 4.7
54 @ 11.25
65 @ 18.75
54 @ 5.6
70 @ 13.5
87 @ 22.5
61 @ 6.6
80 @ 15.75
100 @ 26.25
70 @ 7.5
91 @ 18.0
115 @ 30.0
Rapid Rinse 6 6 6 6 5 5
Fill @ lb of Salt
8 @ 3.0
18 @ 6.75
30 @ 11.25
10 @ 3.75
24 @ 9.0
40 @ 15.0
7 @ 4.7
15 @ 11.25
25 @ 18.75
8 @ 5.6
18 @ 13.5
30 @ 22.5
9 @ 6.6
21 @ 15.75
35 @ 26.25
10 @ 7.5
24 @ 18.0
40 @ 30.0
Operating Pressure:20 -125 psi or 1.4 – 8.8 kg/Centimeter
2
, Operating Temperature: 34 - 110° F or 1.1 – 43.3° C Acceptable Salt Type: Sodium Chloride
All Systems above tested at 35psi +/- 5 psi, pH of 7.5 +/- 0.5, Capacity Testing Flow Rate = 50% of the rated service ow rate for the various size systems
These water softener systems have been tested by WQA and conform to NSF/ANSI 44 for specic performance claims as veried
and substantiated by test data. The rated salt eciencies above were also determined in accordance with NSF/ANSI 44 and
are only valid at the salt dosage referenced above. An eciency rated water softener is a demand initiated regeneration (DIR)
softener which also complies with specic performance specications intended to minimize the amount of regenerant brine
and water used in its operation. Eciency rated water softeners shall have a rated salt eciency of not less that 3350 grains
of total hardness exchanged per pound of salt (based on NaCl equivalency) (477 grams of total hardness exchanged per kilogram
of salt), and shall not deliver more salt than its listed rating. The rated eciency of the water softener, the salt dosage at that
eciency, the capacity at that salt dosage and that of the eciency is only valid at the stated salt dosage. Eciency is measured
by a laboratory test described in NSF/ANSI 44. The test represents the maximum possible eciency the system can achieve.
Operational eciency is the actual eciency achieved after the system has been installed. It is typically less than the eciency
due to individual application factors including water hardness, water usage, and other contaminants that reduce the water
softener’s capacity. These systems are not intended to be used for treating water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system. Refer to the system Installation and Service Manuals for set-up
and programming instructions.
Contact your local dealer for parts and service. See your owners manual for warranty information.
Tested and Certied by the WQA
to NSF/ANSI Standard 44 & 372 for
softener performance & lead free
compliance and CSA B483.1
Pentair Residential Filtration, LLC
13845 Bishops Drive Suite 200
Brookeld, Wisconsin 53005
PHONE: (262)-238-4400
Rev. F 7/16/19
C US
Valve Cycle Time
Settings (minutes)
5800 PERFORMANCE DATA
FLECK 5800/5810/5812 XTRI Service Manual • 45

Related product manuals