Installation 5
Location
Locatethepumpasnearthewatersourceaspractical.
Makethepiperunasshortandstraightaspossible,
especially if a suction lift is required.
Careful attention should be taken to assure that net
positivesuctionheadavailable(NPSHA)exceedsnet
positivesuctionheadrequired(NPSHR)bythepump
or reduced performance and severe pump damage may
result.Ifindoubt,checkwithyournearestSta-Rite
professional dealer. Install pump in a clean, dry and
drained location readily accessible for inspection and
maintenance. Provide ample ventilation.
Pump Foundation
Heavy parts. Use care and proper equipment
when handling pump for installation. Pump should be set
on a concrete foundation which is sufficiently substantial
to absorb vibration and which provides a permanent and
rigid support.
There are several types of permanent pump / foundation
installations in use. Those pictured here are typical.
• Ifgroutisused,topofconcreteshouldbeleftrough
to provide a good bonding surface.
• Foundationshouldslopeawayfrompumptoprevent
liquid from pooling.
Piping
System piping should be at least one commercial pipe
size larger than pump connections and flow velocity
should not exceed eight (8) feet per second.
NOTICE Take care to align piping with pump case.
Misalignmentorexcessivepipestraincancause
distortion of pump components resulting in rubbing,
breakage and reduced pump life.
Support pipe in such a way that no force is exerted on
pump connections. Check alignment as follows: with the
pump shut down and isolation valves closed, remove
pipe flange bolts. If the mating flanges come apart or
shift, misalignment is present and causing pressure
on the connections. Adjust pipe supports until flanges
mate without any force. This procedure can be done
throughout piping system.
Refertothefollowingpagesforrecommendedand
not recommended practices in suction connections in
centrifugal installations.
6546 0412
Concrete Foundation
Tack
Weld
Steel Channel
Drainage
Alignment
Shims
Concrete
Foundation
Shims
Grout
Dam
Drainage
Concrete
Foundation
Wedges
Various Heights
Anchor Bolts
Drainage
Anchor Bolt
Pump or Motor Frame
Grout
Pump or Motor Frame
1/2” or thicker Sole Plate
tapped for hold down bolts

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair STA-RITE and is the answer not in the manual?

Pentair STA-RITE Specifications

General IconGeneral
ModelSTA-RITE
CategoryWater Pump
BrandPentair
Seal TypeMechanical
Motor TypeTEFC (Totally Enclosed Fan Cooled)

Related product manuals