18 • WHOLE HOUSE WATER SOFTENING SYSTEM
HOW TO PROGRAM THE END USER’S LEVEL
To began, verify that the control is in the Service Mode:
Press the SCROLL BUTTON to advance to the next setting.
The following settings are available in the End User’s Level:
1. TIME OF DAY
The control will display:
• Press the UP or DOWN ARROW to program the time of day.
Press the SCROLL BUTTON to advance to the next setting.
2. IMMEDIATE REGENERATION MODE
The control will display:
• If the control is left in this position, the timer will countdown from 10 to 0, initiating a regeneration at 0.
• To avoid an immediate regeneration, press the SCROLL BUTTON before the timer reaches 0.
Press the SCROLL BUTTON to advance to the next setting.
3. DELAYED REGENERATION MODE
The control will display:
• If the control is left in this position, the unit will regenerate at the programmed time. The display will
remain in the Delayed Regeneration Mode until the regeneration has begun.
• To cancel the Delayed Regeneration Mode, press the SCROLL BUTTON.
Press the SCROLL BUTTON to return to the Service Mode.
Time of Day GL Remaining
Set Time of Day
Regen in 10 sec
Regen @ (2.00 am)