TPD1327E Chapter 4
Page 25
How to clean the gauze strainer of the
fuel lift pump
1. Remove the cover complete with the joint (A3)
from the top of the fuel lift pump (A1) and remove
the gauze strainer (A2).
2. Wash carefully all of the sediment from the lift
pump body.
3. Clean the gauze strainer, the joint and the cover.
4. Assemble the lift pump. Use a good joint and
ensure that the lift pump body and the cover are
tted together correctly because leakage at this
point will let air into the fuel system.
5. Eliminate the air from the fuel system through the
lter vent point, see page 30.