Questions and Answers

  • H
    hunter77Aug 13, 2025
    What to do if the Phcbi Accessories incubator does not operate at all?
    • H
      henrywilsonAug 13, 2025
      If the Phcbi Accessories incubator isn't operating, ensure it's correctly plugged into a power outlet. Also, check if the circuit breaker at the power source is active, or if there has been a power failure.
  • C
    Cindy CruzAug 17, 2025
    Why is the CO consumption too much in Phcbi MCO-18ACL Accessories?
    • N
      Norma HicksAug 17, 2025
      Excessive CO consumption in your Phcbi Accessories incubator could be due to: * Frequent opening of the outer and inner doors. * Gas leakage at the connection or pinhole on the gas tube. * An incompletely sealed inner door gasket. * The access port at the upper left corner being open.
  • H
    hchangAug 20, 2025
    What to do if the chamber temperature is not equal to the set temperature in Phcbi Accessories?
    • T
      Timothy SpencerAug 20, 2025
      If the chamber temperature isn't reaching the set temperature, ensure that the ambient temperature is at least 5°C less than the set temperature. Also, check that the outer door was not closed while the inner door was left open.
  • B
    Beverly LeblancAug 25, 2025
    What to do if the CO gas density does not coincide with the set value in Phcbi MCO-18ACL?
    • M
      Mark ScottAug 25, 2025
      If the CO gas density doesn't match the set value, check that the secondary pressure is set to 0.03 MPa(G) (0.3 kgf/cm2(G), 4.4 psi(G)). Also, inspect the gas tube for any clogs or kinks. Ensure the humidifying pan is filled with sterile distilled water.
  • N
    Noah GriffinAug 28, 2025
    What to do if normal cultivation cannot be done and chamber gas density is suspect in Phcbi Accessories?
    • E
      Edward LeonAug 28, 2025
      If normal cultivation is failing and you suspect the chamber gas density, the environment around the Phcbi Accessories incubator might not be normal, possibly due to a nearby source of contaminated gas. Additionally, check if the incubator is installed in an enclosed space.
  • E
    Emily CohenSep 1, 2025
    Why is the key operation disabled on my Phcbi MCO-18ACL?
    • K
      kpattersonSep 1, 2025
      The key operation is disabled because the key lock function is set to ON mode.
  • T
    Tyler HerreraSep 4, 2025
    What to do if the chamber humidity does not rise in Phcbi Accessories?
    • V
      vegaraymondSep 4, 2025
      If the chamber humidity isn't rising, ensure the humidifying pan is filled with sterile distilled water.
  • K
    Kimberly WrightSep 8, 2025
    Why CO gas is not being injected in Phcbi MCO-18ACL Accessories?
    • J
      Jon BlackwellSep 8, 2025
      The CO control method for the gas density is the ON-OFF method. CO gas is intermittently injected as the gas density in the chamber approaches the set value. Also, the gas is not injected until the temperature of the CO sensor becomes stable enough approx. 1 hour, after turning ON the power switch or recovering from power failure.