EasyManua.ls Logo

Phcbi MCO-80ICL - User Manual

Phcbi MCO-80ICL
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MCO-80ICL
Please read the operating instructions carefully before using this product, and keep the operating
instructions for future use.
See page 39 for model number.
Operating Instructions
CO
2
Incubator
This product is for research use only.
Not for clinical diagnosis or treatment of humans or animals.

Questions and Answers

Summary

Introduction

Precautions for Safe Operation

Labels on Unit

Environmental Conditions

Incubator Components

Control Panel and Keypad

Overview of the control panel and keypad functions, including indicators and keys.

Remote Alarm Terminal

Details the function and connection of the remote alarm output terminal.

Installation Site

Installation

Connection of CO2 Gas Cylinder

Provides instructions and safety warnings for connecting the CO2 gas cylinder.

Cautions for Using Equipment in Chamber

Prevent Contamination

Cautions for Culture

Start-Up of Unit

Setting of Chamber Temperature and CO2 Density

Key Lock Function

Alarms & Safety Functions

Setting of Alarm Resume Time

Routine Maintenance

Sterilizing of Chamber and Attachments

Procedure for cleaning and sterilizing the incubator chamber and its internal parts.

Filling Water Reservoir

Calibration

Temperature Calibration

Step-by-step guide to calibrate the temperature control system of the incubator.

CO2 Calibration

Procedure for calibrating the CO2 density control system for accurate measurements.

Troubleshooting

Disposal of Unit

Automatic CO2 Cylinder Changeover

Auto Water Supply System

Specifications

Performance

Summary

Introduction

Precautions for Safe Operation

Labels on Unit

Environmental Conditions

Incubator Components

Control Panel and Keypad

Overview of the control panel and keypad functions, including indicators and keys.

Remote Alarm Terminal

Details the function and connection of the remote alarm output terminal.

Installation Site

Installation

Connection of CO2 Gas Cylinder

Provides instructions and safety warnings for connecting the CO2 gas cylinder.

Cautions for Using Equipment in Chamber

Prevent Contamination

Cautions for Culture

Start-Up of Unit

Setting of Chamber Temperature and CO2 Density

Key Lock Function

Alarms & Safety Functions

Setting of Alarm Resume Time

Routine Maintenance

Sterilizing of Chamber and Attachments

Procedure for cleaning and sterilizing the incubator chamber and its internal parts.

Filling Water Reservoir

Calibration

Temperature Calibration

Step-by-step guide to calibrate the temperature control system of the incubator.

CO2 Calibration

Procedure for calibrating the CO2 density control system for accurate measurements.

Troubleshooting

Disposal of Unit

Automatic CO2 Cylinder Changeover

Auto Water Supply System

Specifications

Performance

Phcbi MCO-80ICL Specifications

General IconGeneral
ModelMCO-80ICL
BrandPHCbi
Capacity80 L
CO2 Range0% to 20%
Humidity Range40 to 95% RH

Related product manuals