MCO-80ICL
Please read the operating instructions carefully before using this product, and keep the operating
instructions for future use.
See page 39 for model number.
Operating Instructions
CO
2
Incubator
This product is for research use only.
Not for clinical diagnosis or treatment of humans or animals.

Questions and Answers

  • T
    tracy38Aug 6, 2025
    What to do if my Phcbi Accessories unit does not operate?
    • D
      Daniel ReedAug 6, 2025
      If your Phcbi Accessories unit isn't operating, make sure it's correctly plugged into a power outlet. Also, check the circuit breaker at the power source or whether there has been a power failure.
  • K
    Katherine SmithAug 12, 2025
    Why is CO2 consumption too high in my Phcbi MCO-80ICL Accessories?
    • B
      Bonnie HernandezAug 12, 2025
      Excessive CO2 consumption in your Phcbi Accessories could be due to several reasons: * The door is opened frequently. * There is any gas leakage at the connection or pin hole on the tube. It is recommended to replace the tube once a year. * An access port is opened.
  • D
    Donald RhodesAug 18, 2025
    What to do if chamber humidity does not rise in Phcbi Accessories?
    • M
      Matthew FletcherAug 18, 2025
      If the chamber humidity isn't rising, make sure the water reservoir is filled with sterile distilled water and that the no humidifying mode is not active.
  • R
    Ronald GarzaAug 25, 2025
    Why does it take so long to recover the gas density in Phcbi MCO-80ICL?
    • N
      natalie19Aug 25, 2025
      If the gas density takes a long time to recover, even with normal gas pressure, the HEPA filter in the gas piping may be clogged with dust, preventing proper gas flow.
  • J
    Jim HuangAug 30, 2025
    Why is CO2 gas not being injected in my Phcbi MCO-80ICL?
    • J
      Jason MuellerAug 30, 2025
      The CO2 injection system is ON-OFF controlled and injects gas intermittently when the set density is close. Injection might stop for 15 seconds but it is not abnormal.

Summary

Introduction

Precautions for Safe Operation

Labels on Unit

Environmental Conditions

Incubator Components

Control Panel and Keypad

Overview of the control panel and keypad functions, including indicators and keys.

Remote Alarm Terminal

Details the function and connection of the remote alarm output terminal.

Installation Site

Installation

Connection of CO2 Gas Cylinder

Provides instructions and safety warnings for connecting the CO2 gas cylinder.

Cautions for Using Equipment in Chamber

Prevent Contamination

Cautions for Culture

Start-Up of Unit

Setting of Chamber Temperature and CO2 Density

Key Lock Function

Alarms & Safety Functions

Setting of Alarm Resume Time

Routine Maintenance

Sterilizing of Chamber and Attachments

Procedure for cleaning and sterilizing the incubator chamber and its internal parts.

Filling Water Reservoir

Calibration

Temperature Calibration

Step-by-step guide to calibrate the temperature control system of the incubator.

CO2 Calibration

Procedure for calibrating the CO2 density control system for accurate measurements.

Troubleshooting

Disposal of Unit

Automatic CO2 Cylinder Changeover

Auto Water Supply System

Specifications

Performance

Phcbi MCO-80ICL Specifications

General IconGeneral
ModelMCO-80ICL
BrandPHCbi
Capacity80 L
CO2 Range0% to 20%
Humidity Range40 to 95% RH