EasyManua.ls Logo

Philips FW C717 - TAPE ADJUSTMENT AND CHECK PROCEDURES; Recording Adjustments; Playback Adjustments

Philips FW C717
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
* For Dolby version only
# For Auto-reverse version only
TEST
CASSETTE
RECORDER
MODE
MEASURE
ON
READ ON
ADJUST
with to
ADJUST DOLBY PLAYBACK LEVEL *
DECK A
DECK B
Playback
TCC-130
(4822 397 30269)
200nWb/m
PLAY
LEFT RIGHT
1 or 2
LEFT RIGHT
PLAY
mV-meter
mV-meter
Check
limits see fig.1
548mV ±0.5dB
3641(L), 3642(R)
3635(L), 3636(R)
SBC420
(4822 397 30071)
CHECK PLAYBACK FREQUENCY RESPONSE
PB. FREQ. RESP.
PLAY FWD
PLAY REV #
Check
548mV ±1dB
7 or 8
General
TEST
CASSETTE
RECORDER
MODE
MEASURE
ON
READ ON
ADJUST
with to
ADJUST MOTOR SPEED
SBC420
(4822 397 30071)
3150Hz
DUBBING
PLAY B
PLAY A
1 or 2
LEFT RIGHT
frequency
counter
3622 *
3620
check
HIGH SPEED
NORMAL SPEED
SBC420
(4822 397 30071)
3150Hz
1 or 2
LEFT RIGHT
SBC420
(4822 397 30071)
10kHz
1 or 2
LEFT RIGHT
PLAY
PLAY FWD
PLAY REV #
W&F-meter check only
mV-meter
left hand screw
right hand screw
max. output level
& left=right
CHECK WOW & FLUTTER
DECK A & B
ADJUST AZIMUTH
5040Hz ± 0.5%
3150Hz ± 0.5%
3150Hz -0.8/+1.8%
0.4 % DIN or
0.35 % CCIR *
DECK A & B
f(Hz)
level(dB)
figure. 1
Dolby version
4dB
3dB
12.5k
10k
250
f(Hz)
level(dB)
Non-Dolby version
8dB
6dB
12.5k
4k
250
80
8dB
Recording
TEST
CASSETTE
RECORDER
MODE
MEASURE
ON
READ ON
ADJUST
with to
5 or 6
LEFT RIGHT
mV-meter
3773
RECORDED
CASSETTE
1 or 2
LEFT RIGHT
LEFT RIGHT
PLAY
mV-meter check only limits see fig.2
mV-meter
420mV
CrO
2
CrO
2
RECORD
CrO
2
RECORD
RECORDED
CASSETTE
1 or 2
LEFT RIGHT
PLAY
THD-meter check only 3%
CrO
2
RECORD
mV-meter
3655 & 3556
RECORDED
CASSETTE
LEFT RIGHT
PLAY
170mV ± 1dB
PRE-ADJUST BIAS AND BIAS-SYMMETRY
DECK B
Inject 3mV signals
100Hz, 250Hz, 1kHz,
10kHz, 12.5kHz
via 3 or 4
CHECK OVERALL FREQUENCY RESPONSE AND DISTORTION
Inject 1kHz 8.85mV
via 3 or 4
Remark: If high frequencies are not within limits, decrease bias and re-measure.
If distortion is too high increase bias and re-measure.
ADJUST DOLBY RECORD LEVEL *
7 or 8
Remark: If measured value is out, re-adjust record level up or down slightly to attain play level.
* For Dolby version only
9 or 10
check
Inject 400Hz 8.85mV
via 3 or 4
3785 *
995mV
left = right
check only
750mV ± 1.5dB
RECORD
FERRO
f(Hz)
level(dB)
figure. 2
Dolby version
5dB
3dB
12.5k
10k
250
f(Hz)
level(dB)
Non-Dolby version
8dB
10dB (HSD)
6dB
10k
4k
250
100
8dB
10dB (HSD)
9A-6
9A-6

Table of Contents

Other manuals for Philips FW C717