PHILIPS 4000 04 DIAGNOSTIC MODE
7/8
If temperature is over 100°C, the backlight change from GREEN to YELLOW
(HD Models) or WHITE to RED (EP Models). is is a ALERT message to
avoid heating the boiler over dangerous temperature.
ERROR: the absorbed current is KO or the temperature does not increase;
check the wiring from the boiler to the CPU/POWER board (JP19 Electrical
diagram), the wiring of the NTC temperature-sensor (JP13 Electrical diagram)
and its correctly operation.
4.2. SteamOut
is document describes the Steam-Out procedure; the application is used in order to empty the heater.
Press the Z5 button for 3sec to reset a parameters of the Grinder (Only for EP models)
e grinder parameters will be set to its initial value a screen with the text
“RESET GRINDER PARAMETERS” is shown.
ERROR: e display doesnt change, repeat the procedure.
e steam out procedure is carried out when there is the need to operate/repair parts of the hydraulic circuit
under pressure. is procedure is not mandatory, but if necessary only for the EP models, before executing the
steam out procedure, decalcify the machine taking care to remouve the Aquaclean lter from the appliance.
In case the lter on the machine is active (or its in the machine) provide the consumer with a new one.
To enter in SteamOut
e machine enters in Steam-Out mode by holding pressed together:
the “ESPRESSO LUNGO” button and the MENU button;
while switching on the machine by main switch behind the machine.
Once entered the Steam Out mode the display shows the “STEAM OUT” indica-
tion. Buttons can be released
IMPORTANT NOTE: to execute the Steam-out procedure the Ntc sensor must
work correctly; if some errors occurs on Ntc during the steam-out, the procedure
cant continue and an error message is shown on the display.
Check the wiring of the NTC temperature-sensor (JP13 Electrical diagram) and
its correctly operation.
IMPORTANT NOTE: to execute the Steam-Out procedure the DREGDRAWER
must be in place and the DOOR must be closed. If these 2 conditions are not
respected a warning message is shown on the display and the Steam-Out is inter-
rupted