Overview
OperatingManualPNOZms1p
20967EN11
7
2 Overview
2.1 Scope
} ExpansionmodulePNOZms1p
} Jumper774639
2.2 Unitfeatures
Theproducthasthefollowingfeatures:
} Monitoringof2independentaxes
} Connectionperaxis
1incrementalencoder
or
2proximityswitches
or
1incrementalencoderand1proximityswitch
} Measuredvariables:
Standstill
Speed(8valuescanbeset)
Directionofrotation
} Axistypes,inputdevicetypesandresetmodecanbeselectedinthePNOZmultiCon
figurator
} Statusindicatorsfor
Supplyvoltage
Incrementalencoder
Proximityswitch
Axisstatus,standstillandexcessspeed
Faultsonthesystem
} Proximityswitchconnectiontechnology:Pluginconnectionterminals(eithercage
clampterminalorscrewterminal)
} Connectiontechnologyincrementalencoder:
FemaleRJ45connector
} GalvanicisolationbetweentheconnectionsX1,X12andX22
} Max.4speedmonitorscanbeconnectedtothebaseunit