PNOZ s11
Operating Manual PNOZ s11
21693-EN-11
| 18
Relay outputs 750111 751111
External contact fuse protection,
auxiliary contacts
Max. melting integral 160 A²s 160 A²s
Blow-out fuse, quick 10 A 10 A
Blow-out fuse, slow 6 A 6 A
Blow-out fuse, gG 6 A 6 A
Circuit breaker 24 V AC/DC,
characteristic B/C 6 A 6 A
Contact material AgCuNi + 0,2 µm Au AgCuNi + 0,2 µm Au
Conventional thermal current
while loading several contacts
750111 751111
Ith per contact at UB DC;
AC1:240V,DC1:24V
Conv. therm. current with 1 con-
tact 6 A 6 A
Conv. therm. current with 2 con-
tacts 6 A 6 A
Conv. therm. current with 3 con-
tacts 6 A 6 A
Conv. therm. current with 4 con-
tacts 6 A 6 A
Conv. therm. current with 5 con-
tacts 6 A 6 A
Conv. therm. current with 6 con-
tacts 5,7 A 5,7 A
Conv. therm. current with 7 con-
tacts 5,3 A 5,3 A
Conv. therm. current with 8 con-
tacts 5 A 5 A
Times 750111 751111
Switch-on delay
With automatic start after power
on typ. 30 ms 30 ms
With automatic start after power
on max. 50 ms 50 ms
Delay-on de-energisation
With E-STOP typ. 18 ms 18 ms
With E-STOP max. 30 ms 30 ms
With power failure typ. 18 ms 18 ms
With power failure max. 30 ms 30 ms
Environmental data 750111 751111
Climatic suitability EN 60068-2-78 EN 60068-2-78
Ambient temperature
Temperature range -10 - 55 °C -10 - 55 °C
Storage temperature
Temperature range -40 - 85 °C -40 - 85 °C