Pilz PNOZ s11 Specifications

General IconGeneral
TypeSafety relay
Number of safety contacts3
Rated voltage24 V DC
Rated current6 A
Supply voltage24 V DC
Semiconductor outputNo
Stop Category0
PL e acc. EN ISO 13849-1Yes
Category 4 acc. EN 954-1Yes
SILCL 3 acc. IEC 62061Yes
SIL 3 acc. IEC 61508Yes
Width22.5 mm
Contact configuration3 N/O
Auxiliary contacts1
Operating principleSingle-channel operation
StandardsEN 60204-1

Summary

Introduction

Definition of Symbols

Explains the meaning of warning symbols used in the document for safety and information.

Safety

Intended Use and Regulations

Defines the product's purpose, applicable standards, and safety guidelines.

Safety Assessment

Highlights the need for safety assessment according to the Machinery Directive.

Qualified Personnel and Liability

Outlines requirements for personnel and conditions invalidating warranty.

Unit Features

Safety Features

Details the safety functions and requirements met by the unit.

Block Diagram and Terminals

Presents the functional block diagram and terminal configuration.

Function Description and Installation

Timing Diagram

Illustrates the timing of input signals and output states.

Control Cabinet Installation

Provides guidelines for installing the safety relay in a control cabinet.

Wiring and Preparation

Preparing for Operation

Details the steps required before the unit can be operated.

Feedback Loop and Connections

Connection to Base Units

Explains how the feedback loop is connected to various base units.

Application Examples

Single Device Configuration

Shows an application example for a single device setup.

Combined with PNOZ s4

Illustrates an application example using the unit with PNOZ s4.

Operation and Faults

Status and Error Indicators

Describes the meaning of LED indicators for status and errors.

Faults and Malfunctions

Details potential faults and malfunctions and their remedies.

Dimensions

Technical Details

General and Electrical Data

Covers general certifications, voltage, current, and power specifications.

Input and Relay Output Specs

Details input parameters and relay output contact ratings.

Utilisation Categories

Specifies utilisation categories for AC and DC loads.

Environmental and Timing Data

Provides environmental conditions and timing specifications.

Mechanical, EMC, and Vibration Data

Details mechanical properties, EMC compatibility, and vibration resistance.

Safety Characteristic Data

Presents key safety parameters like SIL and PL values for the product.

Classification and Supplementary Data

ZVEI CB241 Classification

Describes interface classes and specific values according to ZVEI standard.

Service Life and PFH Value

Discusses service life graphs and the PFH value for safety.

Service Life Graphs

Permitted Operating Height

Voltage Reduction for Altitude

Details voltage reduction requirements for operation at higher altitudes.

Order Information and Compliance

Order Reference

Lists product types, features, terminals, and order numbers.

EC Declaration of Conformity

States the product's compliance with EU machinery directives.