PNOZ X2
Operating Manual PNOZ X2
1003353-EN-08
| 7
Unit features
} Positive-guided relay outputs:
– 2 safety contacts (N/O), instantaneous
} Connection options for:
– E-STOP pushbutton
– Safety gate limit switch
– Start button
} LED display for:
– Supply voltage
– Switch status of the safety contacts
Safety features
The safety relay meets the following safety requirements:
} The circuit is redundant with built-in self-monitoring.
} The safety function remains effective in the case of a component failure.
} The correct opening and closing of the safety function relays is tested automatically in
each on-off cycle.
Block diagram/terminal configuration
*Insulation between the non-marked area and the relay contacts: Basic insulation (over-
voltage category III), Protective separation (overvoltage category II)