PNOZ X2
Operating Manual PNOZ X2
1003353-EN-08
| 7
Unit features
} Positive-guided relay outputs:
2 safety contacts (N/O), instantaneous
} Connection options for:
E-STOP pushbutton
Safety gate limit switch
Start button
} LED display for:
Supply voltage
Switch status of the safety contacts
Safety features
The safety relay meets the following safety requirements:
} The circuit is redundant with built-in self-monitoring.
} The safety function remains effective in the case of a component failure.
} The correct opening and closing of the safety function relays is tested automatically in
each on-off cycle.
Block diagram/terminal configuration
PNOZ X2
*Insulation between the non-marked area and the relay contacts: Basic insulation (over-
voltage category III), Protective separation (overvoltage category II)

Other manuals for Pilz PNOZ X2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pilz PNOZ X2 and is the answer not in the manual?

Pilz PNOZ X2 Specifications

General IconGeneral
CategorySafety Relay
Width22.5 mm
Height87 mm
Depth121 mm
MountingDIN Rail
Rated Current per Channel6 A
Supply Voltage24 V DC
Contacts2 N/O
Stop Category0
Weight200 g
StandardsEN 60204-1