PSEN cs3.1p/M12
Operating Manual PSEN cs3.1p/M12
1003296-EN-09
| 36
Operating distances 541059 541060 541064
Actuator 2
Type PSEN cs1.1 PSEN cs1.1 PSEN cs1.1
Assured operating dis-
tance Sao 10 mm 10 mm 10 mm
Typical operating dis-
tance So 25 mm 25 mm 25 mm
Assured release dis-
tance Sar 33 mm 33 mm 33 mm
Typical release dis-
tance Sr 29 mm 29 mm 29 mm
Repetition accuracy
switching distances 10 % 10 % 10 %
Change of operating
distance with temperat-
ure changes +-0,1mm/°C +-0,1mm/°C +-0,1mm/°C
Typ. Hysteresis 3 mm 3 mm 3 mm
Actuator 3
Type
PSEN cs3.1 low profile
glue
PSEN cs3.1 low profile
glue
PSEN cs3.1 low profile
glue
Assured operating dis-
tance Sao 5 mm 5 mm 5 mm
Typical operating dis-
tance So 10 mm 10 mm 10 mm
Assured release dis-
tance Sar 20 mm 20 mm 20 mm
Typical release dis-
tance Sr 12 mm 12 mm 12 mm
Repetition accuracy
switching distances 10 % 10 % 10 %
Change of operating
distance with temperat-
ure changes +-0,01mm/°C +-0,01mm/°C +-0,01mm/°C
Typ. Hysteresis 2 mm 2 mm 2 mm
Actuator 4
Typ
PSEN cs3.1 low profile
screw
PSEN cs3.1 low profile
screw
PSEN cs3.1 low profile
screw
Assured operating dis-
tance Sao 5 mm 5 mm 5 mm
Typical operating dis-
tance So 10 mm 10 mm 10 mm
Assured release dis-
tance Sar 20 mm 20 mm 20 mm
Typical release dis-
tance Sr 12 mm 12 mm 12 mm
Repetition accuracy
switching distances 10 % 10 % 10 %
Change of operating
distance with temperat-
ure changes +-0,01mm/°C +-0,01mm/°C +-0,01mm/°C
Typical hysteresis 2 mm 2 mm 2 mm