1-9
a. Ensure that the Unitrol valve knob is in the OFF position. Remove the manifold pressure
tap plug and connect an accurate pressure gauge (range of 0-16" w.c. in 0.1" increments)
or manometer.
b. Light the pilot burner (see 1.5.2) for the unit being tested and adjust the thermostat to light
the main burners.
c. The installed pressure gauge reading should be the same, ±0.1", as that marked on the data
plate inside the door. If the pressure is correct go to step e, if not, adjust the pressure.
d. To adjust the pressure, remove the regulator adjustment screw cover (see Figure 1-3). Use
a flat tip screwdriver to adjust the screw until the proper pressure is reached. Turning the
screw clockwise will increase the pressure, counterclockwise will decrease the pressure.
e. When the pressure is correct, install the regulator adjustment screw cover.
f. To remove the pressure gauge, turn gas control valve to OFF. Remove the gauge and install
the pressure tap plug.
g. Now that the pressure is set for proper operation, set the main burner flame. Unlock the air
collars by loosening the set screw for the collars. See Figure 5. Turn the Unitrol valve knob
to ON and turn thermostat to light the main burners.
h. Adjust the shape and size by raising or lowering the air collars to achieve a soft blue flame
with well defined inner cones.
i. When the flames have been properly adjusted, lock the collars in place with the set screw
provided.
1.5.4 Initial Cleaning
When the fryer is shipped, many of its parts are covered with a thin coat of oil for protection. Before
the fryer is ready for cooking it must be cleaned. This will remove the oil coating and any foreign matter
that may have accumulated during storage and shipment. Perform the cleaning as described below.
Figure 1-2 Gas Valve
Showing Location of the
Pressure Regulator and
Pilot Adjusters
ENGLISH

Table of Contents

Other manuals for Pitco 35C+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pitco 35C+ and is the answer not in the manual?

Pitco 35C+ Specifications

General IconGeneral
Oil Capacity35-40 lbs
BTU90, 000 BTU/hr
Weight180 lbs
Gas TypeNatural Gas or Liquid Propane
Model35C+
TypeFloor Fryer
Temperature Range200°F - 400°F
Dimensions (Alternative)35" L x 20" W x 17" H

Related product manuals