1-11
b. Set the thermostat at 325°F and wait for the temperature reading on the thermometer to rise.
As the temperature rises toward 325°F watch the thermometer closely.
c. If the shortening temperature reaches 350°F and the burners DO NOT turn off, turn the
thermostat down. Keep lowering the thermostat setting until the burners go out.
CAUTION
If the burners do not turn off at the lowest thermostat setting, the thermostat
could be defective. Contact your representative immediately.
d. Let the fryer cycle 4 to 6 times before checking the temperature. Compare the thermometer
temperature against the thermostat setting. If the values are more than 5°F apart, calibrate
the thermostat using the appropriate calibration procedure in this manual.
1.5.6 Thermostat Calibration
a. Place the tip of the thermometer in the shortening approximately 1" above the temperature
sensors.
b. Set the Thermostat to 325°F and wait for the temperature reading on the thermometer to rise.
c. Let the fryer cycle 4 to 6 times to ensure that the temperature has stabilized. Compare the
thermometer temperature against the thermostat setting. If the values are more than 5°F
apart, calibrate the thermostat using the appropriate calibration procedure.
ENGLISH

Table of Contents

Other manuals for Pitco 35C+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pitco 35C+ and is the answer not in the manual?

Pitco 35C+ Specifications

General IconGeneral
Oil Capacity35-40 lbs
BTU90, 000 BTU/hr
Weight180 lbs
Gas TypeNatural Gas or Liquid Propane
Model35C+
TypeFloor Fryer
Temperature Range200°F - 400°F
Dimensions (Alternative)35" L x 20" W x 17" H

Related product manuals