4-8
C
YES
Reset switch and
check trip setting.
NO
Is the High Limit
switch open?
B
YES
NO
Does the
HEATING light
come on?
YES
NO
NO
Ensure that the heating
elements are down. Check
the interlock switch per 4.7
and replace if necessary.
Are the heating
elements down and is
the interlock
working?
Does the fryer
heat up?
A
Replace the
temperature
probe.
NO
YES
Test the temperature
probe as described in 4.6.
Is the temperature probe
defective?
YES
Verify continuity of the leads
which provide 24 VAC power,
and the potentiometer and
p
robe si
g
nals to the module.
YES
Replace the
module.
Test the
temperature control
module as described in
4.5. Is the module
defective?
NO
YES
Replace the
potentiometer
Test the
temperature set
potentiometer as described in
4.4. Is the potentionmeter
defective?
NO