20 /20
Use, maintenance and calibration
M0171G
13 TECHNICAL DATA
Measurement system
TURBINE
Resolution
(nominal)
Hi Flow
0.010 lit/pulse
Low Flow
0.005 lit/pulse
Flow Rate
(Range)
K24 COL. BLACK
5 ÷ 120 (Litres/minute)
FOR DIESEL FUEL, WATER,.
K24 COL. BEIGE
5 ÷ 100 (Litres/minute)
FOR WATER/UREA SOLUTION..
Operating pressure (Max)
10 (Bar) 145 (psi)
Bursting pressure (Min)
40 (Bar)
Storage temperature (Range)
-20 ÷ + 70 (°C)
Storage humidity (Max)
95 (% RU)
Operating temperature (Range)
-10 ÷ + 50 (°C)
Flow resistance
0.30 Bar at 100 lit/min.
Permissible Viscosity (Range)
2 ÷ 5.35 cSt
Accuracy (10÷90 litres/min)
+/- 1% after calibration within
Reproducibility (Typical)
+/- 0,3 (%)
Screen
Liquid crystals LCD. Featuring:
- 5-figure partial
- 6-figure Reset Total plus x10 / x100
6-figure non reset Total plus x10 / x100
Power Supply
2x1.5 V alkaline batteries size AAA
Battery life
18 ÷ 36 months
Weight
0.4 Kg (included batteries)
Protection
IP65
BULB (pulser)
Max current: 1 mA
Max Voltage: 3 V
MaxLoad: 0.003 Watt