7.1.2 Programming of the step (segment)
Press Display Do
4
STEP
Red display visualizes
01 - t
.
Green display shows step time.
5
Increases, decreases value on
green display.
N.B.:Each cycle is composed of
max. 18 programmable steps,
after those it skips automatically
to point 10.
Enter the step duration in
hours:minutes.
N.B.: Set
--.--
for endless time or
end
for cycle end (if not all steps
are used) and skip to point 10.
6
STEP
Red display visualizes
01 - S
. Green
display shows the step setpoint
(temperature that has to be
reached within given time).
With
or select the setpoint
(temperature reached at step end).
7.1.3 Programming of the alarm/auxiliary (if congured)
Press Display Do
7
STEP
Red display visualizes
01 - A .
Green display shows
A1 -o f
or
A1 -o n
.
If
A L .1
is not programmed as
auxiliary time (
a.o.r.s.
) skip to
point 10.
8
Select auxiliary output status
during the step:
A1 -o n
for active
output and
A1 -o f
for not active
output.
9
STEP
Back to point 4.
7.1.4 End programming
Press Display Do
10
STEP
The controller backs to STOP
mode, saving the cycle. Red
display visualizes
stop
.