9.5 Waiting step end
This function has been conceived to control kilns working cycles, whenever the
kiln cannot follow gradients programmed by the user. If at step end the di erence
between process and setpoint values is greater than the value on
parameter 21
m.G.s. e.
, controller starts with the next step only after waiting for the
time programmed on parameter 20
w.t.s.e.
, or when this gap becomes lower than
parameter 21
m.G.s. e.
Temperature
Time
SETPOINT
Step 1 Step 2
Waiting time step end (Par. 20)
Step and max. gap (Par. 21)
Step 3
PROCESS
To exit manually from this function press
. To disable this function x at 0 end
step waiting time
w.t.s.e.
. During end step
waiting red display shows
w ai t
instead of
the cycle number.
9.6 Loading default values
This procedure allows to restore all default settings.
Press
stop
and follow the points below:
Press Display Do
1
CYC LE
Press for 5”. Green display shows
0000
with 1st digit  ashing, red
display visualizes
pass
.
2
STEP
Flashing digit on green
display changes.
Enter the password
9999
.
3
STEP
Device loads default settings.
Entering password
9999
all default parameters will be loaded. If it is necessary to
cancel and reset also the cycles, enter password
9989
.