User manual - ATR902 - 17
Temperature
Time
PROCESS
SETPOINT
Step 1
Step 2
Black-out
Step 2
Step 3
NB: After a power-o the chronometer
will restart from 00:00.
9.4.2 Recovery with programmable recovery gradient
To enable cycle recovery with a recovery gradient, enter on parameter 22
r.i . c y .
a value (degrees/hour if temperature) greater than 1. At restarting if the kiln
temperature (process) is lower than the setpoint, ATR902 locks the working cycle
executing a step with the rising gradient set on parameter 22
r.i . c y .
to return to
the setpoint value entered before the power failure and the cycle restarts form
that point. In recovery mode the point on the right of the red display ashes and
display shows
rec
instead of the cycle number.
Temperature
Time
SETPOINT
Step 1
Step 2
Black-out
Step 2
Recovery step with
programmable
gradient (Par. 22)
Step 3
PROCESS
Recovery will start only for holding or
rising steps.
To exit manually from recovery mode
press
or .