EasyManua.ls Logo

Pixsys ATR226 - User Manual

Pixsys ATR226
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ATR226
Controller / Regolatore
User manual / Manuale installatore
Question and Answer IconNeed help?

Do you have a question about the Pixsys ATR226 and is the answer not in the manual?

Pixsys ATR226 Specifications

General IconGeneral
TypeTemperature Controller
Output TypeRelay, SSR
DisplayDual 4-digit LED
Input TypeThermocouple, RTD
Size48x48 mm
Operating Temperature0 to 50°C
CommunicationRS485

Summary

Safety Guide Lines

Model Identification

Technical Data

General Features

Specifications like displays, operating temperature, material, and weight.

Hardware Features

Software Features

Dimensions and Installation

Electrical Wirings

Wiring Diagram

Diagrams and explanations for power supply, analogue input, and sensor connections.

Wiring Diagram (Outputs and Inputs)

Diagrams for relay outputs, SSR output, and digital input wiring.

Display and Keys Functions

Numeric Indicators (Display)

Explanation of the main and secondary display indicators.

Meaning of Status Lights (Led)

Description of the status lights and their meaning.

Keys

Details on the functions of the Up, Down, and Set buttons.

Controller Functions

Modifying Main Setpoint and Alarm Setpoint Values

How to change the main setpoint and alarm setpoint values using the keyboard.

Auto-Tuning

Procedure for automatic tuning to calculate regulation parameters.

Manual Tuning

Manual procedure for adjusting PID algorithm parameters.

Automatic Tuning

Automatic tuning for clear regulation without PID knowledge.

Soft-Start

Function to follow a gradient to reach the setpoint at startup.

Automatic;Manual Regulation for % Output Control

Selecting automatic or manual control of the output percentage.

Digital Input Functions

Description of digital input functions and their configuration.

Configuration

Loading Default Values

Procedure to restore the device to its factory settings.

Table of Configuration Parameters

Sensor, Decimal Point, and Degree Parameters

Parameters for sensor input, decimal point display, and degree type.

Command, Action Type, PID, Setpoint, Calibration Parameters

Parameters for command output, action type, PID, setpoints, and calibration.

Error, Protection, Reset, Delay, Auto;Manual, Softstart Parameters

Parameters for error handling, setpoint protection, reset, delay, and softstart.

Digital Input and Alarm 1 Parameters

Parameters for digital input contact type and Alarm 1 settings.

Alarm 1 Reset;Delay and Alarm 2 Selection Parameters

Parameters for Alarm 1 reset/delay and Alarm 2 selection.

Alarm 2 Parameters and PID Tuning Settings

Parameters for Alarm 2 settings and PID tuning.

PID Tuning Parameters: Deviation, Gap, Band, Integral Time

Advanced PID tuning parameters like deviation, gap, band, and integral time.

Alarm Intervention Modes

Absolute and Band Alarm Mode Illustrations

Illustrations and descriptions of absolute and band alarm modes.

Deviation Alarm Mode Illustrations

Illustrations and descriptions of upper and lower deviation alarm modes.

Table of Anomaly Signals

Configuration EASY-UP

Summary of Configuration Parameters

Summary of Alarm and PID Configuration Parameters

Summary of parameters related to Alarms, PID, and output controls.

Notes; Updates

Related product manuals