7. When the Individual
Fuzzy Logic mode is on,
the fuel burns out too
intensively.paliwa
reduce fuel feeding rate by lower setting of the parameter Fuel
correction in Fuzzy Logic mode. See sec. 7.8,
check whether incompletely burnt fuel comes from operation in
SUPERVISION mode. If YES- adjust this mode acc. sec. 11,
check whether incompletely burnt fuel is produced by frequent
change-over from SUPERVISION to OPERATION mode and V/V,
Cycle order OPERATION acc. sec. 35,
if the regulator has the option of fuel type selection - make sure
the correct fuel type has been selected (see sec. 7.10 Fuzzy
Logic mode does not allow burning a blend of fine coal and ECO-
pea coal),
check whether correct type of boiler/ burner has been selected.
See sec. 21.1
open fully fan baffle and/ or return flap
clean off ducts supplying air to the furnace
change Fuzzy Logic settings in: MENU Service Settings
Boiler Settings Burner Settings Fuzzy Logic (accessible to
boiler manufacturers only)
8. When Fuzzy Logic mode
is active, combustion is
too intensive and the
furnace lowers into
retort.
increase fuel feeding rate by higher setting of the parameter Fuel
correction in Fuzzy Logic mode. See sec. 7.8
check whether too intensive combustion occurs in SUPERVISION
mode. If YES - adjust this mode acc. sec. 11,
check whether too intensive combustion is caused by the setting
Cycle order OPERATION - see sec. 35,
if the regulator has the option of fuel type selection - make sure
the correct fuel type has been selected (see sec. 7.10),
check whether correct type of boiler has been selected. See sec.
21.1.
change Fuzzy Logic settings in: MENU Service Settings
Boiler Settings Burner Settings Fuzzy Logic (accessible
only to boiler manufacturers only)
9. The temperature is
measured incorrectly
Check if there is a good thermo contact between the
temperature sensor and measured surface,
Check if sensor wire not goes too closely to network wire,
Check if sensor is connected to terminal,
Check if sensor is not broken check with point 11.9
10. In the DHW=SUMMER
mode, the radiators are
hot and the boiler
overheats.
increase the setting of the parameter: HUW pump operation
extension time to cool down the boiler. See sec. 36,
increase the setting of the parameter: max. HUW temperature to
enable excessive heat discharge to HUW container. See sec. 40,
Note: inform the users of high temperature of hot utility water!
11. the DHW pump is active
even if the DHW tank
has been filled.
Set the parameter HUW pump operation time extension = 0
12. The boiler overheats
despite disabled airflow.
the reason may be boiler defect or improper chimney design -
lack of protection against too excessive flue draught.