Release Notes
Polycom RealPresence Group Series, Version 4.1.1.1
24 Polycom, Inc.
Interoperability
Polycom Touch
Control
GS-12938 4.1.1 After you perform a factory
restore and an update to a
Polycom Touch Control, the
system only shows the
Language screen for 10-15
seconds before displaying the
Pair screen.
Touch Home on the
Polycom Touch Control to
access the Language
screen.
Interoperability
Polycom Touch
Control
GS-12464 4.1.1 After the Polycom Touch Control
initializes, the far-end camera
control does not work in the first
call.
Leave the Camera screen,
then navigate back to it.
Interoperability
Polycom Touch
Control
GS-8253 4.0.2 The RealPresence Group
system does not wake up when
paired with a Polycom Touch
Control that is sending USB
content.
Wake up the
RealPresence Group
system before sending
USB content from the
Polycom Touch Control.
Interoperability
Polycom Touch
Control
GS-6823 4.0.1 When a you attempt to pair a
Polycom Touch Control running
software version 4.0.0 with a
RealPresence Group system
running software version 4.0.1,
the pairing fails because the
versions are not compatible.
The error message incorrectly
states that the Polycom Touch
Control should be running
software version 4.0.0, instead
of stating that software version
4.0.1 is required.
Ensure Polycom Touch
Control software version
4.0.1 software is installed
before trying to pair it with
a RealPresence Group
system running software
version 4.0.1.
Interoperability
Radvision
GS-13522 4.1.1.1 The RealPresence Group
Series systems do not receive
video from the Radvision Scopia
100 P10 Gateway.
Interoperability
Radvision
GS-9798 4.0.2 When a RealPresence Group
system is the MCU in a SIP call
to a Radvision Scopia XT1000
system and a Radvision Scopia
XT5000 system, the Radvision
Scopia XT1000 system displays
frozen video.
Instead of using the SIP
protocol, use H.323.
Interoperability
Radvision
GS-2160 4.0.0 When in a mixed H.323/SIP call
with a Radvision Scopia
XT1000 as the MCU, the
RealPresence Group system
that connected as a H.323
endpoint does not transmit
video.
Make the call using either
H.323 or SIP.
Category Issue ID
Found in
Release Description Workaround