Start-up
Before starting to operate the machine, please check that the protective and safety systems
are working and also the hydraulic hoses and oil level.
Before each start-up, the condition of the electrical cables must be checked.
Check that the saw blade is firmly seated before each use.
If a fault occurs during operation, the machine must be shut down immediately and secured
so it cannot be switched on accidentally or started-up by unauthorised persons.
Driven by electric motor (type E)
Machines with 400 V motor
The machine must only be operated on electric circuits equipped with 30 mA FI fault current
protection or a Portable Residual Current Device (PRCD).
Work on electrical equipment must only be carried out by qualified electricians.
Type E22
Connect the machine to the mains:
▪ Mains voltage 400 V (50 Hz)
▪ Circuit-breaker 32 A (tripping characteristic C)
▪ For the feed, a cable cross-section of at least 10 mm² must be used.
This cable cross-section is only a minimum specification. In the event of a lengthy
supply cable, its size must be determined by an electrician.
▪ Turn the switch to the ON position.
1
Neutral position 2 On position
Note the rotation direction of the electric motor (see arrow on motor).
If the motor is rotating in the wrong direction:
A phase inverter in the plug controls the direction of rotation of the motor (press in the disc
in the plug with a screwdriver and turn 180˚).
5
5.1
5.1.1
Start-up
17