Function Prog.
no.
Level
1)
Standard value
Relay output QX21 module 1
Off | On
9050 C
Relay output QX22 module 1
Off | On
9051 C
Relay output QX23 module 1
Off | On
9052 C
Relay output QX21 module 2
Off | On
9053 C
Relay output QX22 module 2
Off | On
9054 C
Relay output QX23 module 2
Off | On
9055 C
Burner control
Pre-purge time 9500 E 15 s
Nominal output pre-purging 9504 E
Paramount 30: 14,5 kW
*)
Paramount 40: 19,5 kW
*)
Paramount 60: 32,0 kW
*)
Paramount 80: 44,6 kW
*)
Paramount 95: 52,0 kW
*)
Paramount 115: 57,0 kW
*)
Nominal output ignition load 9512 E
Paramount 30: 14,5 kW
*)
Paramount 40: 19,5 kW
*)
Paramount 60: 32,0 kW
Paramount 80: 44,6 kW
*)
Paramount 95: 52,0 kW
*)
Paramount 115: 57,0 kW
*)
Nominal output Partial load 9524 E
Paramount 30: 5,6 kW
*)
Paramount 40: 9,0 kW
*)
Paramount 60: 12,0 kW
Paramount 80: 17,0 kW
*)
Paramount 95: 20,0 kW
*)
Paramount 115: 25,0 kW
*)
Nominal output full load 9529 E
Post-purge time 9540 E 10 s
Fan output/speed increase 9626 E Paramount 30: 214.3
Paramount 40: 150.0
Paramount 60: 106.6
Paramount 80: 76.1
Paramount 95: 65.0
Paramount 115: 60.0
Programming
7308272-03 03.14 Paramount three 30-115 kW 75