EasyManua.ls Logo

Power Electronics SD 300 Series - 13 Trouble Shooting

Power Electronics SD 300 Series
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SD300 PROFINET
POWER ELECTRONICS
50
TROUBLE SHOOTING
13. TROUBLE SHOOTING
No.
Symptoms
Resolution
1
ERROR indicator and
CPU indicator are
both turned off.
Power is not supplied to the communication module.
• Correctly Install the communication module to the drive.
• Check the connector pins on the communication module
for bends or other defects.
If the problem persists after taking the measures listed
above, it may indicate that the hardware is malfunctioning.
Contact a service agent near you or the Power Electronics
customer support.
2
ERROR indicator is
turned on, and CPU
indicator is turned off.
The hardware is malfunctioning. Contact a service agent
near you or the Power Electronics customer support.
3
ERROR indicator and
CPU indicator are
flashing
synchronously in 1
second intervals.
• Check the connector pins on the communication module
for bends or other defects.
If the problem persists after taking the measures listed
above, it may indicate that the hardware is malfunctioning.
Contact a service agent near you or the Power Electronics
customer support.
4
CPU indicator is
flashing in 1 second
intervals, and ERROR
indicator is flashing in
2 second intervals.
Check the communication link where the LAN cable is
connected and ensure that the LINK indicator is turned on.
If the LINK indicator is turned off, check the LAN cable and
ensure that it is properly connected to the link port.
• Check to ensure that the communication module device
name and [] Telegram Mode parameter settings match the
network configuration at the PLC.
Check to ensure that the IP address assigned to the
communication module is not already used by other
devices on the same network.
If the problem persists after taking the measures listed
above, it may indicate that the hardware is malfunctioning.
Contact a service agent near you or the Power Electronics
customer support.
13