X4 | SERVICE MANUAL
12. Updating of the Firmware using ArmoniaPlus v1.2
On the bottom of the Armonia Workspace panel, click on
“Match” & on the top panel, click on “Discovery” in order
to load the unit.
This procedure may take up to 5 seconds.
Once properly loaded, the Amplier and its Serial Number
should appear on the window.
By hovering the Mouse onto the unit, the following
information will be displayed.
EXAMPLE:
Model: X4 Dante
Serial: 00505285
Device Address: 169.254.7.192
Firmware: 1.8.6.160 (OLD VERSION)
Click on “System List”.
Check on the amplier required to Update Firmware.
Click on the “Update Selected”.
Upon clicking the “Update Selected”, the installation of
Firmware begins.
INDEX
After completed the updating, Armonia will show the
latest rmware of the Amplier.
Firmware: 1.8.7.15 (NEW VERSION)