45
X4 | SERVICE MANUAL
Once the Discovery Phase is complete (10 seconds) the square
will turn Green. Double click on the Unit to continue the test.
Apply a 1KHz 1Vpp audio signal to CH1
Check for presence of the signal in all the other channel’s VMeters
Apply a 1KHz 1Vpp audio signal to CH1
Check for presence of output signal in all channels.
Peak Current: 43.46 +/- 5%
RMS Current: 30.46 +/- 5%
Repeat this procedure by connecting the PC to the other ETH port on the unit’s SLOT Board
13
15 16
14
Function
Generator
Input 1
INDEX
Use the following list as a checklist once the amplier has been successfully repaired.
1. The Device operates on all Mains congurations
2. The front LEDs operate correctly
3. Ethernet communication
4. Discovery
5. Correct Armonìa communication
6. Input signal present on all channels
7. Output signal present on all channels
8. Armonìa displays correct meter readings on all channels
9. The fans operate accordingly to the ampliers’s status
19. Final Checklist