DOES THE SMART ROLL REQUIRE MAINTENANCE?
Maintenance is minimal, check the roll periodically as you would any idler roll for ease of turning and for buildup on the roll. Also make sure
that the CSR is free and rolls smoothly on the belt surface. If mounted properly, it should give years of service.
WHY ISN’T MY SMART MONITOR RAMPUP TIMER DOING ANYTHING WHEN I START MY CONVEYOR?
See the two options for wiring the Smart Monitor in Section 4 “Wiring the Smart Monitor”. The ramp-up timer will only keep the relay
energized when the Smart Monitor first receives power. When 120 VAC is applied to the power cable, the timer function will energize the
control relay. After the time has elapsed the relay will de-energize unless the belt is running above the set speed.
UNIVERSAL MOUNT SMART ROLL MOUNTING INSTRUCTIONS
Attention must be given to the location of the Smart Roll so that it is always in contact with the belt. Failure to mount properly may void
warranty and could cause damage to conveyor belt and other components.