PR8000 9mt 4x2000W METAL HALIDE
01-04-2011
11.4.1 LOWERING HANDLE BAR BRACKET IN CASE OF EMERGENCY
WARNING: It is strictly prohibited to raise the stabilisers when the lighting tower mast is
raised.
In the event of damage to the hydraulic pump or generating set, it is possible to move the hydraulic
components of the lighting tower by using the manual pump installed.
Insert the handle (51) of the manual pump that is inside the cabinet (52).
Engage the levers (41, 42, 43, 44 and 45) located on the control panel in relation to the hydraulic
components you want to move, and at the same time, engage the manual pump. When you have
achieved the desired position, release the lever.
In order to move another hydraulic component, repeat the procedure.