PR8000 9mt 4x2000W METAL HALIDE
01-04-2011
REMEDY
The lamp could not be relight, it is necessary to wait for the lamp to cool down(about 15 minutes).
CAUSE
The automatic earth leakage relay has been tripped.
REMEDY
Rearm the automatic earth leakage relay.
15. REPLACE THE LAMP AND LENSES
In the event you need to replace the lamps or the lenses, open the lamp by unlocking the hook
placed on the rear cover and replace the lamp. Close the cover.
Type of lamp: Metal halide
Base: K12s-7
Nominal power: 2000 W
Nominal voltage: 240 V – 50 Hz