PR8000 9mt 4x2000W METAL HALIDE
01-04-2011
REMEDY
Check the electrical connection.
CAUSE
The hydraulic gear box does not work.
REMEDY
Check that the automatic earth leakage relay is armed. If it is not armed rearm it.
Check the electrical system of the hydraulic gear box.
Check the oil level inside the hydraulic gear box, and top up if necessary.
Replace the hydraulic gear box and contact PR POWER directly.
FAULT
• The lowering telescopic mast lever does not work.
CAUSE
Defective electrical connection.
REMEDY
Check the electrical connection.
CAUSE
The hydraulic gear box fails.
REMEDY
Manually jack down the mast, using the handle inside the door (refer to chapter “11.4.1 Lowering
Handle Bar Bracket in Emergency”), to lower the mast.
FAULT
• One or more lamps do not light.
CAUSE
Defective lamps.
REMEDY
Before replacing the lamp, it is advised you test the lamp by installing the lamp that has failed in a
floodlight where the lamp was previously working.
FAULT
• The lamp fails to light.
CAUSE
The lamp has been accidentally turned off.