PR8000 9mt 4x2000W METAL HALIDE
43
TL116-11-00-03
01-04-2011
REMEDY
Check the fuel level monitor and the electrical connection.
CAUSE
The fuel float does not work.
REMEDY
Check the fuel float and the electrical connection. If the sensor is blocked, replace it.
FAULT
When the engine is running the hour meter does not work.
CAUSE
The hour meter does not work.
REMEDY
Check the hour meter and the electrical connection.
FAULT
The automatic earth leakage relay trips during the operation of the lighting tower.
CAUSE
There has been a current leak, during the use of the auxiliary socket.
REMEDY
Check the electrical system connected to the auxiliary socket, check that the amp draw does not
exceed the required level.
CAUSE
Electrical connections interrupted.
REMEDY
Check the external electrical system and if the problem continues contact PR POWER.
CAUSE
Connection to Earth not correctly carried out.
REMEDY
Check that the connection to Earth is correct.
FAULT
The raising and lowering lever of the telescopic mast does not work.
CAUSE
Defective electrical connection.