PR8000 9mt 4x2000W METAL HALIDE
01-04-2011
CAUSE
Radiator inlet or outlet clogged.
REMEDY
Clean carefully.
CAUSE
Radiator fan does not work.
REMEDY
Check the fan.
CAUSE
The engine protection panel “DAS” TP0401 is defective.
REMEDY
Replace the panel.
FAULT
• The lighting tower shuts down. The battery charge indicator light is on.
CAUSE
The battery is defective.
REMEDY
Replace the battery.
CAUSE
The engine’s alternator fails.
REMEDY
Check it alternator and if problem continues contact PR POWER.
CAUSE
The engine protection panel “DAS” TP0401 is defective.
REMEDY
Replace the panel.
FAULT
• After refueling, the fuel level monitor does not move.
CAUSE
The fuel level monitor does not work.