PR8000 9mt 4x2000W METAL HALIDE
41
TL116-11-00-03
01-04-2011
FAULT
Ouput voltage unstable.
CAUSE
Irregular engine speed.
REMEDY
The engine is set to the correct speed.
CAUSE
The alternator is defective.
REMEDY
Replace the alternator and if problem continues contact PR POWER.
FAULT
The lighting tower shuts down. The low oil pressure indicator light is on.
CAUSE
The oil level is low.
REMEDY
Check the level and add oil if necessary.
CAUSE
The pressure switch is defective.
REMEDY
Replace the pressure switch.
CAUSE
The “DAS” TP0401 engine protection panel is defective.
REMEDY
Replace the panel.
FAULT
The lighting tower shuts down. The high water temperature indicator light is on.
CAUSE
The level of the coolant in the radiator is low.
REMEDY
Check the level and add coolant if necessary.