PR8000 9mt 4x2000W METAL HALIDE
37
TL116-11-00-03
01-04-2011
WARNING: It is strictly prohibited to raise the stabilisers when the lighting tower is in
vertical position at its maximum height.
WARNING: The lighting tower is designed to withstand 110 km/h winds at its maximum
height. In the event the tower is operating in a windy location, retract the telescopic mast
slowly.
In case of hydraulic gear box or generating set engine failure, it is still possible to lower the mast.
Make reference to the chapter “11.4 HYDRAULIC GEAR BOX”.
12.12 STOPPING THE ENGINE
Switch off all the lamps via the circuit breakers (34-35-38-39).
Allow the engine to conintue to operate for approximately 1 minute, then turn the starting key (40)
to the stop position.
In an emergency it is still possible to stop the generating set by pressing the stop button (18).