TC.B TC.E TC.J TC.K
TC.L TC.N TC.R TC.S
TC.T TC.U TC.W3 TC.W5
TC.Lr
1 2
Power up
1 2
0000
PASSW.
Txt 1
50.0
%
12.0
3
3
0000
9999
1 2
NO
ADV.SET
Txt 2
NO
YES
1 2
3
VOLT
IN TYPE
Txt 3
VOLT
CURR
LIN.R
POTM
TEMP
1 2
3
50.0
RELAY1
Txt 57
3
75.0
RELAY2
Txt 57
3
1 2
1 2
2-10
V.RANGE
Txt 4
2-10
0-10
1-5
0-5
0.2-1
0-1
1 2
3
CURR
IN TYPE
Txt 3
3
4-20
I.RANGE
Txt 5
0-20
4-20
1 2
3
LIN.R
IN TYPE
Txt 3
3
3W
CONNEC.
Txt 6
4W
3W
2W
1 2
3
POTM
IN TYPE
Txt 3
3
TEMP
IN TYPE
Txt 3
3
0
R 0%
Txt 7
0000
9999
1 2
3
2500
R 100%
Txt 8
0000
9999
1 2
3
Pt
SENSOR
Txt 10
Pt
NI
TC
1 2
3
YES
ADV.SET
Txt 2
3
Ni
SENSOR
Txt 10
3
TC
SENSOR
Txt 10
3
100
Pt TYPE
Txt 16
1000
-
10
1 2
3
3W
CONNEC.
Txt 6
4W
3W
2W
1 2
100
Ni TYPE
Txt 17
1000
-
50
1 2
3
3W
CONNEC.
Txt 6
4W
3W
2W
1 2
TC.K
TC.TYPE
Txt 18
0.0
DISP.LO
Txt 13
999.9
-199.9
1 2
111.1
DEC.P
Txt 12
1111
111.1
11.11
1.111
1 2
3
UNIT
%
Txt 11
@C
mA
rpm
(69 units)
1 2
3
1.0
1.2
1.1
3
100.0
DISP.HI
Txt 14
999.9
-199.9
1 2
3
DISP
REL.UN
Txt 15
DISP
PERC
1 2
3
3
3
N.O.
R1.CONT
Txt 20
3
N.O.
N.C.
1 2
50.0
R1.SETP
Txt 21
9999
-1999
1 2
3
INCR
ACT.DIR
Txt 22
INCR
DECR
1 2
3
1.0
R1.HYST
Txt 23
250.0
0.1
1 2
3
SETP
R1.FUNC
Txt 19
SETP
WIND
ERR
POW
OFF
1 2
3
O.I.W
R1.CONT
Txt 27
3
O.I.W
C.I.W
1 2
60.0
SETP.LO
Txt 29
9999
-1999
1 2
3
70.0
SETP.HI
Txt 28
9999
-1999
1 2
3
1.0
R1.HYST
Txt 30
250.0
0.1
1 2
3
WIND
R1.FUNC
Txt 19
3
OPEN
ERR.ACT
Txt 34
3
CLOS
OPEN
1 2
ERR
R1.FUNC
Txt 19
3
POW
R1.FUNC
Txt 19
OFF
R1.FUNC
Txt 19
3
3
1.3
@C
UNIT
Txt 9
@C
@F
1 2
3
3
@C
@F
%
A
bar
cm
ft
ft/h
ft/min
ft/s
g
gal/h
gal/min
GW
hp
hPa
Hz
in
in/h
in/min
in/s
ips
K
kA
kg
kJ
kPa
kV
kW
kWh
l
l/h
l/min
l/s
m
m/h
m/min
m/s
m/s2
m3
m3/h
m3/min
mA
mbar
mils
min
mm
mm/s
mol
MPa
mV
MW
MWh
N
Ohm
Pa
pH
rpm
s
S
t
t/h
uA
um
uS
V
W
Wh
yd
[blank]
3
INT
CJC
Txt 63
54
55
Fast setpoint adjustment
and relay test
1 Increase setpoint
2 Decrease setpoint
3 Save and exit the menu
1 and 2 simultaneously = change relay state
1.0 = Default state Line 1
shows input signal.
Line 2 shows UNIT.
By pressing 1 and
2 simultaneously line 3
alternates between
A.Out and TAG.
Line 4 shows relay and
communication status.
1.1 = Only if password-
protected.
1.2 = Only if FastSet is acti-
vated and the relay
function is setpoint.
1.3 = Not valid for these input
signals: 0...20 mA and
voltage.
1.4 = Only if input signal is
temperaure.
1.5 = The relay can only be
deactivated by an ope-
rator and only if the
normal conditions for
deactivation are met.
If the input signal still
has a value that will
activate the relay, the
relay will latch again.
Continued on the page
Routing diagram ADV.SET
ROUTING DIAGRAM
If no key is activated for 1 minute, the display will return to the default
state 1.0 without saving configuration changes.
1 Increase value / choose next parameter
2 Decrease value / choose previous parameter
3 Save the chosen value and proceed to the next menu
Hold 3 Back to previous menu / return to menu 1.0 without saving
Continued on the next page
Selectable
UNITS:

Table of Contents