Make sure that the electrical characteriscs of building electric network
follow the technical specificaons of the oven which can be found on the
idenficaon plate located on the back panel and in the electrical table
below.
Use a dedicated circuit breaker for the oven. The maximum distance between
the right side of the oven and the electrical receptacle is 6 .
Properly size the circuit breaker and network cables.
The oven MUST be properly grounded. In the event of damage due to
improper grounding to third pares and/or to the equipment, the will be held
responsible and will characterized as negligence due to the non-compliance
with the standards.
There is an equipotenal point on the rear panel of the oven.
·
·
·
INSTALLATION AND OPERATION MANUAL
·Note: The equipment has an interconnect connector for other equipment. This
connector is intended to keep several devices with the same electrical potential. Not
necessarily the grounding of a local connection. This connector on the rear of the
device is identified by the symbol on the right:
16
Exhaust
Outlets
Power
Cable
6
(1.8m)
Maximum
Distance
Circuit
Breaker
Air Inlet
1 ⁄"
(40 mm)
27 ⁄"
(700 mm)
NEMA
6-30
3x10AWG
32
6.2
7.2
60
Single
208
240
USA
Power
(kW)
Circuit
Breaker
(A)
Cable Socket
Region
Voltage
(V)
Phases
Freq.
(Hz)
Europe
230
Single
50 6.9
32
3x4mm²
32A
(2P+E)
230
Multi
50 6.9
32
5x2,5
mm²
32A
(4P+E)
380
Multi
50 6.6
16
16A
(3P+N+E)
5x2,5
mm²
400
Multi
50 6.9
16
16A
(3P+N+E)
5x2,5