Make sure that the electrical characteriscs of building electric network
follow the technical specificaons of the oven which can be found on the
idenficaon plate located on the back panel and in the electrical table
below.
Use a dedicated circuit breaker for the oven. The maximum distance between
the right side of the oven and the electrical receptacle is 6 .
Properly size the circuit breaker and network cables.
The oven MUST be properly grounded. In the event of damage due to
improper grounding to third pares and/or to the equipment, the will be held
responsible and will characterized as negligence due to the non-compliance
with the standards.
There is an equipotenal point on the rear panel of the oven.
·
·
·
INSTALLATION AND OPERATION MANUAL
·Note: The equipment has an interconnect connector for other equipment. This
connector is intended to keep several devices with the same electrical potential. Not
necessarily the grounding of a local connection. This connector on the rear of the
device is identified by the symbol on the right:
16
Exhaust
Outlets
Power
Cable
6 
(1.8m)
Maximum
Distance
Circuit
Breaker
Air Inlet
1 "
(40 mm)
27 "
(700 mm)
NEMA
6-30
3x10AWG
32
6.2
7.2
60
Single
208
240
USA
Power
(kW)
Circuit
Breaker
(A)
Cable Socket
Region
Voltage
(V)
Phases
Freq.
(Hz)
Europe
230
Single
50 6.9
32
3x4mm²
32A
(2P+E)
230
Multi
50 6.9
32
5x2,5
mm²
32A
(4P+E)
380
Multi
50 6.6
16
16A
(3P+N+E)
5x2,5
mm²
400
Multi
50 6.9
16
16A
(3P+N+E)
5x2,5
mm²